Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
International Journal of Laboratory Medicine ; (12): 1885-1886, 2014.
Article in Chinese | WPRIM | ID: wpr-453076

ABSTRACT

Objective To investigate the diagnostic value of the soluble transferrin receptor (sTfR)in non-adult iron deficiency anemia (IDA)and its differential diagnostic value between IDA and anemia of chronic disease(ACD).Methods 26 cases in the IDA group involved 12 males and 14 females,aged 1 month to 15.5 years;33 cases in the ACD group involved 17 males and 16 females, aged 2 months to 14.0 years;30 cases in the normal control group involved 15 males and 15 females,aged 1 month to 15.5 years. Serum sTfR and ferritin (SF)were detected by the immunonehelomitery,serum iron (SI)was detected by Ferrous Oxazine colori-metric method.Results The gender and age had no statistically significant difference among 3 groups;the SI mean value in the ACD group located between the IDA group′s and the normal control group′s;the SF mean value of the IDA group was significantly lower than that of ACD group (P <0.001)and that of control group (P <0.001),while the sTfR mean value of IDA group was significantly higher than that of the ACD group (P <0.001)and that of the normal control group (P <0.001).The best cutoff of sTfR for the differential diagnosis between IDA and ACD was 3.56 mg/L,its sensitivity,specificity,negative predictive value,posi-tive predictive value and accuracy were 95.12%,93.92%,94.11%,97.53% and 95.50% respectively.Conclusion sTfR has higher sensitivity and specificity for IDA and is conducive to diagnose IDA and differentially diagnose ACD.

2.
Chinese Journal of Nosocomiology ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-592611

ABSTRACT

OBJECTIVE To develop a rapid system for bacteria identification and susceptibility test in 24 hours,and provide bacteriological evidence for the control of nosocomial infection and the timely diagnosis and treatment.METHODS The simple constant temperature box was replaced by revolving constant temperature box;2,3,5-triphenyltetrazolium chloride(TTC) and succinate were added to the culture bottle and the culture medium of drug susceptibility;the concentration of the reactive substrate in the bacterial biochemical tube and the number of the inoculated bacteria were increased at the same time.RESULTS The time of positive blood culture in the revolving constant temperature box was significantly shorter than that in the simple one(?2=74.92,P

SELECTION OF CITATIONS
SEARCH DETAIL